Abstract

In this communication, a thermal model has been developed to predict the performance of hybrid photovoltaic-thermal (PV/T) greenhouse (roof type even span) dryer under forced mode. Based on energy balance, analytical expressions for temperatures of greenhouse air and produce (grape) surface as a function of design and climatic parameters have been developed. The analytical expressions for instantaneous and overall thermal efficiencies have also been developed. The experimental validations have also been carried out for greenhouse room air temperature, crop produce temperature and moisture evaporated etc. under composite climate of New Delhi (28°35'N, 77°12'E, 216 m above MSL). It has been observed that the developed thermal model was in well agreement with experimental data. It has been found that the overall thermal efficiency of hybrid PV/T greenhouse dryer varies from 33 percent to 37.8 percent.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.