Abstract
ABSTRACTIn this paper thermal performance of graphite-based sensible heat storage system with embedded helical coil in rectangular shell was studied. Plain water at four flow rates (0.25 LPM–1.0 LPM) and four inlet temperatures (60°C–90°C) was passed through the graphite bed and charging time was measured. Expanded graphite/water suspension and Al2O3/water nanofluid were also used to study charging behavior of graphite. Results showed that charging time of packed bed was reduced with increase in flow rate and inlet temperature of heat transfer fluid. Charging time using expanded graphite/water solution and nanofluid was 14.2% and 21.2% lesser than water.Abbreviations: hi: internal heat transfer coefficient (W m−2 K−1); HTF: Heat transfer fluid; ho: External heat transfer coefficient (W m−2 K−1); LPM: liter per minute; k: thermal conductivity (W m−1 K−1); TSU: Thermal storage unit
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.