Abstract
The paper presents the results of experimental tests of joints of walls made of autoclaved aerated concrete (AAC). Different joint types were used to connect two walls: trusses, standards profiles and profiles with widened cross-section at the joint as well as polyurethane glue (foam) commonly used for bricklaying of masonry walls. 18 models were tested altogether in five series. The tests were performed on an original test stand in which shearing of wall joints can be realized with minimized bending. Morphology of cracking and mode of failure were analyzed; the load–deflection relationships of tested models and reference models with traditional masonry bonds were also compared. The tests showed differences in cracking and failure mechanisms as well as in load-bearing capacity of different joint types.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.