Abstract

A rough rectangular channel of solar-based air heater (SBAH) is made and tested. The work consists of an effort to perceive the proportion of heat discharge and frictional behavior of air passing over a roughened rectangular channel. The absorber surface of SBAH is roughed with discrete V-down rib and staggered element roughness having different values of relative rib pitch (P/e) that ranged from 6 to 14. Fixed parameters such as relative gap size (g/e), relative staggered element pitch (P'/P), numeral of gaps (Ng), relative staggered element size (r/g), and relative rib height (e/D) are considered 4, 0.4, 3,1, and 0.0433, respectively, all throughout the study. The flow Reynolds number (Re) changes from 4000 to 14,000; consequently the Nusselt number (Nu) and friction factor (f) reach up to 2.16 and 2.73 times, respectively, with respect to plane surface. The optimum rise in terms of thermal-hydraulic performance (THP) is gained analogous to a P/e of 10. The correlation for heat transfer function, R(e+), and roughness function, G(e+), is given to anticipate the performance of roughness.