Abstract

Profiled steel sheeting dry board (PSSDB) system is made of profiled steel sheeting that is connected to the dry board using a self-drilling, self-tapping screw. This study aims to predicts the load-deflection behavior of PSSDB panel system under the influence of geopolymer concrete infill with finite element modeling. To achieve the target objective, the laboratory testing approach and a theoretical system behavior prediction are considered. Through a bending test, the stiffness of PSSDB full board with geopolymer concrete infill (FBGPC) panel is 27.42 kNm2 and the ultimate load is 13.13 kN/m2. The developed finite-element modeling (FEM) successfully predicts the behavior of PSSDB with geopolymer concrete infill panel with >85% accuracy.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.