Abstract

New low global warming potential refrigerant R446A was developed to replace R410A in residential air conditioner. Theory cycle analysis shows that 10% more displacement compressor was recommended for R446A comparing with R410A. The compressor evaluation shows that R446A was similar to that of R410A, and the COP of R446A was higher than that of R410A when the 10% more displacement compressor was used for R446A.The air conditioner evaluation shows that: the capacity of R446A was similar to that of R410A, the COP was higher than that of R410A when the 10% more displacement compressor was adopted for R446 and control algorithm was optimized. R446A was an alternative refrigerant to R410A used in the residential air conditioner.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.