Abstract
In this paper, water-cooled thermoelectric cooler (TEC) for central processing unit (CPU) is developed. Two temperature controls for TEC are proposed and compared to prevent condensation on CPU and save energy. Performances of TEC with the two temperature controls are experimentally investigated under different operating conditions and environmental temperatures. Effects of air velocity and water mass flow rate for the heat sink are investigated under severe environment. Dynamic performance comparisons of three cooling methods, including TEC with and without temperature control and passive water cooling, are investigated under variable operating conditions at severe environment. Experimental results show that temperature of CPU (Tcpu) for SC is lower than that for OC when Tcpu is lower than the set temperature. A higher COP can be kept when air velocity and water mass flow rate is 0.8 ms−1 and 0.042 kg s−1, respectively. The largest temperature variation of Tcpus is lower than 1.5 °C under variable operating conditions at severe environment.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.