Abstract

Experimental research was conducted on the transverse stress of 32m post-tensioned precast simply supported concrete box girder with ballastless track. Vibrating wire strain gauges were embedded in the key sections to monitor the concrete transverse strain. The concrete strain development law was analyzed. The monitored results showed that there were low transverse tensile stresses and the cracking resistance of the girder was enough during pre-tensioning stage. The research findings provided effective experimental data for design and construction quality control.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.