Abstract

This study focuses on thermal sensation of subjects with radiant cooling workstation and desktop fan in hot-humid environment. Twenty-four human subjects participated in the experiments and reported their thermal sensation of the whole body, head, trunk, upper limb and lower limb in hot-humid environment at 26℃, 28℃ and 30℃ in an environmental chamber, respectively. The obtained results show that radiant cooling workstation and desktop fan significantly improved the thermal sensation of subjects in hot-humid environments, but the effect was not obvious at 26℃. The average vote of thermal sensation at 28℃ was between -0.2 and 0, and subjects still had neutral thermal sensation condition although indoor environment was as high as 30℃ while the relative humidity was 80%. Therefore, radiant cooling workstation and desktop fan can extend comfortable temperature range in summer. This study provides a new way for both maintaining comfort in non-neutral environment and saving energy in buildings.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.