Abstract

In this study, an experimental platform was built to investigate the separation performance of 4 designed different separators which had significant influence on ejector-expansion system performance, by means of visualization and heat balance method. The results showed the oblique injection separator with top outlet pipe inserting inside the separation tank presented the best performance, reaching 244 W cooling capacity at −25 °C evaporation temperature. With such separator, the COP of ejector-expansion refrigeration system could be improved by 16.7% at −30 °C evaporation temperature compared with normal refrigeration system. However, as the evaporation temperature increased further, the ejector showed less significant impact on the system performance.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.