Abstract
A passive core cooling system (PCCS) has been installed at the Institute of Nuclear Energy Research Integral System Test facility. It includes three core makeup tanks (CMTs), three accumulators (ACCs), a four-stage automatic depressurization system (ADS), a passive residual heat removal (PRHR) heat exchanger submerged into an in-containment refueling water storage tank (IRWST). The purpose of this research is to study the performance of the PCCS with passive injection during either a pressure balance line (PBL) break or a direct vessel injection (DVI) line break. Five experiments were performed simulating break area ratios of 0.5 to 2.0% (1.88 to 3.77 mm) at either a PBL or a DVI line. The general system response and the interactions of CMT, ACC, PRHR, and IRWST to the effect of core heat removal are observed and discussed. The experimental results show long-term core cooling can be reached for the cases of the PBL break and the DVI-line break following the PCCS actuation procedures.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.