Abstract
The treatment of transformer oil wastewater in the accident oil pond with ozone has no secondary pollution to the environment. The cavitation technique was used to enhance the oxygenation process and hydrocyclone separator to do the pretreatment. After transformer oil sewage enters the hydrocyclone, the separation efficiency reached up to 60%, which reduces the processing load of subsequent cavitation device. Through 10min cycle treatment of ozone in a cavitation device, the oil concentration of the imported wastewater was reduced from 50mg/L to below 5 mg/L, which has reached the Class-I discharge standard of industrial water. The optimal operation parameters of cavitation were studied by adjusting the inlet pipe gap and gas-liquid ratio of cavitation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.