Abstract
The load response rate of the circulating fluidized bed (CFB) boiler is low for its great thermal inertia. In order to increase its load response rate, a new dynamic combined combustion technology featuring co-combustion of CFB coal and pulverized coal (PC) with high gross calorific value (GCV) is put forward. This combined combustion system was set up on a 240 t/h CFB boiler, and PC coal spraying positions, heating values, and heat ratios were evaluated for their effects on load response rate and combustion performance of the CFB boiler. When PC coal is fed from the secondary air pipes, the relative load change rates (RLCRs) exceed 2.0%/min and meet the requirement RLCR for power dispatching (1.5%/min), and the maximum RLCR is 3.69%/min. Moreover, the weighted average of carbon in residue decreases, and the original NOX emission of CFB boiler increases less than 40 mg/Nm3. Results indicate that the dynamic combined combustion of CFB coal and PC coal with higher GCV fed through secondary air pipes in CFB boiler is a feasible technology to increase its relative load response rate.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.