Abstract
In this study, the interface bonding properties of CFST at different ambient temperatures (T) were studied through the push-out test of 20 CFST specimens. The effects of diameter-to-thickness (D/t) ratio and concrete strength (fcu) on the interfacial bonding strength at different ambient temperatures were studied. At the same time, the distribution characteristics of the strain on the steel tube along the axial direction of CFST columns at different temperatures were analyzed. Subsequently, a formula for calculating the inter-facial bonding strength of CFSTs considering the effect of T was proposed. The results showed that the bonding strength calculated using the formulas pro-posed in this paper was in good agreement with the test results, which could serve as a theoretical reference for the design of CFST structures in high-cold regions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.