Abstract

Super-span (20 m) non-prestressed T-section reinforced concrete beams have been in service for more than 30 years and are common in Chinese highway bridges. However, the actual performance of these super-span T-section reinforced concrete (RC) beams that have been reinforced with FRP, including their process of failure from a service state to a failure state, has not been determined. In this study, original RC T-beams, with a 20 m span and retrofitted with FRP, were taken from a highway bridge. Their flexural performance was detected via experiments in a laboratory. The experiments revealed that the sectional strain distribution is more non-uniform. The mid-span ribs clearly play a role in strengthening the section and the bearing reservation was studied based on a subsequent sectional analysis. It became clear that the load-bearing reservation of an old super-span T-beam changes during the entire life of the specimen; not only because of the depression of the resistant capacity and the reinforced measure, but also due to the updates to load codes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.