Abstract

Air-cooled proton exchange membrane fuel cell (PEMFC) system with simplified system composition, low energy consumption and high efficiency is regarded as a reliable power source for the backup and emergency power. Dual air-cooled PEMFC stacks with a rated power of 7.5 kW are used in the experiment to investigate the dynamic response under different current loading rates of 0–20 A and 20–40 A. The experimental results show that stacks perform better under low air flow rate due to the greater influence of the temperature and membrane hydration than stoichiometry on the performance. Similarly, dual air-cooled PEMFC stacks show superior performance under a rapid loading process with the same air flow rate because of higher stack temperature and short-term gas sweeping. The maximum temperature, voltage variance and voltage fluctuation rate of the dual-stacks system increase significantly from 50 ℃, 0.00015 and 1.85 % under current loading of 0–20 A to 57 ℃, 0.00092 and 4.52 % under current loading of 20-40 A, indicating more stringent requirements of thermal management, water management and flow distribution at high current densities. Furthermore, periodic hydrogen purging under current loading of 20–40 A has been proven to improve the performance and consistency of the stacks.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call