Abstract
Aiming at the damage of the prefabricated counter bore at the elbow of the scribble pressure pipeline, a test system is established based on the ultrasonic guided wave technology, and the end echo interference is eliminated by arranging a multi-channel sensor array to achieve accurate positioning of the pipeline damage and return the measured damage Comparing the wave amplitude value with the 3% DAC curve to calculate the pipe damage cross-sectional loss rate, the test results show that the average relative error between the monitored damage cross-sectional loss rate and the actual cross-sectional loss rate is 3.46%, and the average relative error of damage location is 2.05%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.