Abstract

In the process of downhole layered oil recovery, it is necessary to measure the liquid production of each layer in real time, so as to control the oil production plan of each layer in real time according to the oil production plan. Need to use ultrasonic time difference flowmeter to measure the flow in the process of injection and production. Due to the complex and changeable downhole environment, impurities such as sand and bubbles often appear in the process of downhole flow measurement. How to choose a suitable ultrasonic transducer frequency is of great significance to the flow measurement results. At present, common transducer resonance frequencies on the market mainly include 1MHz, 500KHz, 180KHz, and 40KHz. In this paper, the attenuation characteristics of the resonant signal of the transducer in the medium containing impurities are studied through simulation and experiment. The experimental data shows that in the stratified oil recovery system, the receiving effect of the system is best when the transducer frequency is 1MHz.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.