Abstract

In this paper, a large-scale indoor model test with water pressure is conducted in order to investigate the stress and deformation properties of reinforced concrete lining structures with circular cross-sections.Under internal water pressure, the water pressure carried by lining structure is about 20%~40% of total water pressure before cracking and less than 30% after cracking.Under external water pressure, without drainage of outer side of lining, the water pressure carried by lining structure is only less than 40% of total water pressure.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.