Abstract
This paper describes the results of a furnace test conducted on two-way concrete slab with clamped edges. The details of clamped support condition, arrangement of reinforcement, position of displacement transducers and thermocouple trees are described. Detailed experimental data in the form of describing slab cracking, the temperature distributions within the slab, vertical deflections and horizontal displacements are presented. The experimental results show that the temperature distribution along the slab depth was nonlinear and the temperature gradients in the slab were large. Extensive cracks occurred on the top surface of the slab and formed in an elliptical pattern. It is shown that two-way concrete slab with clamped edges has good fire resistance.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.