Abstract
The torque-controlled expansion anchors, undercut anchors,bonded anchors and special inverted conical chemical anchors subjected to tension load, which including single anchor, two anchors, four anchors and eight anchors are tested. Failure mode and tension performance of anchor group are investigated, and test value and calculative value of ultimate load are compared. Experimental results show that some anchor group occur the concrete cone failure under tension load, and others occur steel failure under tension load. Test value and calculative value of ultimate load are compared, and the result meets well.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.