Abstract

Taking an ultra-supercritical pressure once-through boiler as an example, the temperature distribution of the lower membrane water wall is investigated experimentally, the conclusion reveals that increasing the proportion of Zhundong coal can effectively reduce the district heat load, which benefits the temperature uniformity in the lower membrane water wall. When the boiler being operated at middle load, the temperature deviation in lower membrane water wall increase simultaneously, one of the reasons is that the restriction orifice could not adjust the flow rate of working fluid as expected. By adjusting boiler performance, the temperature uniformity of lower membrane water wall can be improved to a certain degree.