Abstract

In order to evaluate characteristics of the liquid film flow and their influences on heat and mass transfer, measurements of the instantaneous film thickness using a capacitance method and observation of film breakdown are performed. Experimental results are reported in the paper. Experiments are carried out at Re =250–10000, Tin=20°C – 50°C and three axial positions of vertically falling liquid films for film thickness measurements. Instantaneous surface waveshapes are given by the interpretation of the test data using the cubic spline method. The correlation of the mean film thickness vs the film Reynolds number is also given by fitting the test data. It is revealed that the surface wave has nonlinear behavior. Observation of film breakdown is performed at Re =1.40×103–1.75×104 and Tin =85°C – 95°C. From experimental results, the correlation of the film breakdown criterion can be obtained as follows: Bd = 1.567×10−6 Re1.183.