Abstract
In steel-concrete hybrid members and structures, to ensure required stress transmission between the steel and the concrete members, shear connectors are generally arranged between the two. A perfobond strip is widely used as the shear connector in various hybrid structures, and when applying the perfobond strip it is important to confirm its shear resistance. In this study, the shear resistance of the perfobond strip without the penetrating rebar is investigated experimentally by employing a simple push-out specimen. As a result, a design formula is proposed for evaluating the shear resistance of the perfobond strip, taking into account the dimensions of concrete block and the thickness of the perfobond plate, as well as the perforation diameter, and the concrete compressive strength.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Proceedings of International Structural Engineering and Construction
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.