Abstract

Abstract This report deals with the experimental study of seismic response behavior of piping systems in industrial facilities such as petrochemical, oil refinery, and nuclear plants. Special attention is focused on the nonlinear dynamic response of piping systems due to frictional vibration appearing in piping and supporting devices. A three-dimensional mock-up piping and supporting structure model wherein piping is of 30-m length and 200-mm diameter is excited by a large-scale (15 m × 15 m) shaking table belonging to the National Research Institute for Earth Science and Disaster Prevention in Tsukuba, Ibaraki. Power spectra of the response vibration and the loading-response relationship in the form of a hysteresis loop under several loading conditions are obtained. The response reduction effect caused by frictional vibration is evaluated and demonstrated in terms of “response reduction factor.”

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call