Abstract
To study the seismic behaviors of full precast shear wall-frame structures with prefabricated shear wall panels and prefabricated frames. Two geometrically identical half-scale two-story two-bay RC shear wall-frame structure specimens were constructed and tested under quasi-static reversed cyclic loading (One specimen named RC-1 is cast-in-place concrete shear wall-frame structure, the other one is a precast specimen named PC-3). The test results show that the specimen PC-3 have similar failure pattern with the specimen RC-1. The experimental investigation indicates that the reliably connected, well-designed and constructed full prefabricated shear wall-frame structures with prefabricated shear wall panels and prefabricated frames, have good seismic performance and can meet the seismic requirements and be used in anti-seismic zone.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: DEStech Transactions on Environment, Energy and Earth Sciences
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.