Abstract

The study aims to investigate the influence of tip clearance on the scour rate of pile-supported horizontal axis tidal current turbine (TCT) and also attempts to correlate time-dependent scour depth of TCT with the tip clearance. A physical model of TCT was placed in a flume for scour test and the scour rate of the fabricated model was investigated. The results suggest that the decrease in tip clearance increases the scour depth. In addition, the shortest tip clearance results in the fastest and most sediment transport. The maximum scour depth reached 18.5% of rotor diameter. Results indicate that regions susceptible to scour typically persist up to 1.0Dt downstream and up to 0.5Dt to either side of the turbine support centre. The majority of the scour occurred in the first 3.5 h. The maximum scour depth reaches equilibrium after 24 h test. An empirical formula to predict the time-dependent scour depth of pile-supported TCT is proposed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.