Abstract

Experimental study was carried on a 300MW swirling combustion pulverized coal firing furnace with put parts of tertiary air as over fire air to reduce NOx emission. The influence of boiler operational condition on the characteristics of NOx emission were studied, such as the content of O 2 at economizer exit, the proportion of the top tertiary air and mass flow of over fired air (OFA). Results show that the content of O 2 at economizer exit and the proportion of the top tertiary air have greater effect on boiler efficiency and NOx emission. It maintain the two parameters about 4% and 135t/h can inhibit NOx emission and have less influence on boiler efficiency; adjusting the opening of over fire air damper blow 60% can influence the NOx emission. After adjustment <;. The concentration of NOx emission concentration can control blow 800mg/Nm 3 . It could provide some technical gist for the same type of boiler.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.