Abstract

The performance of turbine flowmeter and Venturi meter in oil‐water two‐phase flow measurement was investigated. Experiments were carried out on horizontal pipelines of 0.5‐inch, 1.0‐inch and 1.5‐inch diameters, with the total flowrate range of 0.9∼4.5m3/h and the oil volume fraction range of 15% ∼ 85%. Experimental results show that the measurement errors of the turbine flowmeter and the Venturi meter obviously increase, whether the static mixer is installed on the experimental loop or not. Also, the non‐homogeneity of the oil‐water two‐phase flow and the swirl flow produced by the static mixer have negative influence on the performance of turbine flowmeter and Venturi meter. Research work further indicates that the oil fraction has significant influence on the measurement results of Venturi meter.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.