Abstract

Tuned liquid column damper (TLCD) was developed mainly for suppressing horizontal motion of building structures. No relevant research has been found on the suppression of structural pitching vibration by using TLCD. This paper thus presents a detailed experimental investigation on the possibility and effectiveness of applying TLCD to reduce pitching vibration of structures. A theoretical model of TLCD-structure interaction under pitching vibration is first presented to guide the experiments. Then, a large scale experimental model simulating TLCD-structure interaction is designed and a series of free and forced vibration experiments are conducted using different TLCD configurations and parameters. The free vibration experiments indicate that the system damping can be significantly increased by installing the TLCD. The forced vibration experiments show that the peak value of the structural pitching vibration can be effectively mitigated. From the experiments, the influences of various TLCD parameters on con...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.