Abstract

ABSTRACT OH* chemiluminescence and emissions of the convergent swirler module and the Venturi swirler module are studied in a single-element lean direct injection combustor. The OH* chemiluminescence images are captured by a CCD camera with an image intensifier, and the emissions are measured by a gas analysis system. The flame of the Venturi swirler module is closer to the inlet plane of the combustor compared to that of the convergent swirler module. At the equivalence ratio (ϕ) of 0.55, 0.65, and 0.75, the EINOx of the convergent swirler module is 1.02 g/kg, 1.44 g/kg, and 1.98 g/kg, and the EICO is 0.32 g/kg, 0.54 g/kg, and 3.65 g/kg separately. The EINOx of the Venturi swirler module is 0.95 g/kg, 1.37 g/kg, and 2.05 g/kg and the EICO is 0.32 g/kg, 0.93 g/kg, and 5.86 g/kg. The NOx emissions of the two swirler modules are similar. But the CO emission of the convergent swirler module is lower at the ϕ of 0.65 and 0.75. The convergent swirler module has an advantage in reducing emissions. In addition, the influence of the swirl number (S) on OH* Chemiluminescence and emissions of the convergent swirler module is studied. At the ϕ of 0.55, the EINOx is between 0.88 g/kg and 1.17 g/kg and the EICO is between 0.13 g/kg and 0.44 g/kg with different S. With the increase of the S, the NOx emission increases and the CO emission decreases. But at the ϕ of 0.65 and 0.75, with the increase of the S, the NOx emission first increases and then decreases and the CO emission first decreases and then increases.