Abstract
Based on the experimental study of normal-section bearing capacity of four steel reinforced high-strength concrete (SRHC) L-shape short pier shear walls with two-way eccentric compressive load, this thesis discussed the failure pattern and working mechanism and get some general laws about normal-section baring capacity of this kind of specimens. The research results show that: the failure pattern of SRHC L-shape short pier shear wall with two-way eccentric compressive load is classified into two types-large eccentric compression and small eccentric compression; the sectional strain basically fit the plane-section assumption; steel and concrete can practically work cooperatively until the specimens are damaged and the steel of compressive region yielded; the normal section baring properties of the perforated frame member and the trussed frame member were fairly close to each other and the trussed frame has no advantage compared with the perforated one.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.