Abstract

Liquid oxygen chill-down in a horizontal exit-contracted pipe was investigated experimentally. The outer wall temperatures were recorded in the detailed manner. Results show the temperatures in the center length of the pipe decrease first, which shows much different manners from those in the transport pipe. This indicates that liquid accumulates in the center length to form quenching head, which propagates to the both sides of the pipe during the liquid oxygen chill-down process in the exit-contracted pipe. Based on the present set of data, the correlations on temperature of Leidenfrost point was corrected, and critical heat flux was well correlated by new expression from bubble separation theories. Results show that, for high pressure or high flow rate cases, Leidenfrost point is controlled by the increase of instable wave on the liquid propagation area. However, for other cases, Leidenfrost point is controlled by heat transfer.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.