Abstract
Heat transfer to supercritical water flowing upward and downward in a 2×2 rod bundle with wrapped wire was experimentally investigated. The rod bundle consists of four heating rods within out-diameter of 10mm. The rods are arranged in a 2×2 square array and the pitch-to-diameter ratio is 1.18. The bundle is inserted into a square assembly box with round corners. The water as coolant flows upward or downward in the channel between the rod bundle and the assembly box. The pressure ranges from 23 to 26MPa, mass flux ranges from 450 to 1200kg/(m2s), heat flux ranges from 200 to 1000kW/m2, and the fluid temperature ranges from 200 to 450°C. The effects of system parameters including mass flux, heat flux and pressure on the heat transfer are presented, respectively. The heat transfer deterioration occurs at a low G/q ratio in the upward flow, but does not appear in the downward flow. Watts-Chou correlation and Bishop correlation give the best predictions when evaluated against the experimental data both in the upward and downward flow. The experimental data are compared with the bare rod bundle. The comparison indicates that the swirl flow of wrapped wire promotes the heat transfer in the rod bundle.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.