Abstract

Water jet impinging heat transfer is widely used in steel-making industry, nucleate power plants, and many other applications. In this study, an experimental study was carried out in an industry-scale facility. In this test facility, an insulating material was added to simplify the heat-transfer process. The data filter method was used to remove the noise in temperature measurements. Using inverse heat conduction analysis, surface heat flux was obtained, and the inverse heat conduction method was verified. The relative error between the calculated and measured temperature at the bottom surface of the test plate was less than 5%, and the relative error of the inner temperature of the test plate was less than 0.35%. Increasing the surface roughness provided better heat transfer in the stagnation region, which is in agreement with the reported results in the literature. By determining the surface temperature of the test plate, the boiling heat-transfer mode can be identified.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.