Abstract
Heat transfer and pressure drop characteristics of turbulent swirling air flow through a sudden expansion pipe with different swirl angles and different sudden expansion ratios were investigated experimentally. The effect of the sudden expansion ratio, Reynolds number, vane angle and swirl generator location on the heat transfer and pressure drop were examined. The test pipe is uniformly heated and the Reynolds number ranges from 9,000 to 41,000. It was found that inserting a swirl generator inside sudden expansion pipe causes an increase in both the relative mean Nusselt number and the enhancement efficiency of the tested pipe. The enhancement efficiency increases with Reynolds number decreasing while it increases with the increase in sudden expansion ratio and vane angle. A maximum efficiency up to 405% could be achieved. Correlations for Nusselt number and friction factor for the swirl flow are obtained and the performance evaluation criterion to access the real benefits in using the swirl generators of the enhanced tube is discussed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.