Understanding the height effect on the gas-solid flow characteristics in a CFB riser is important as more and more large capacity CFB boilers are used and to be developed. In this study, a cold CFB test rig with a riser of 240mm in LD. and 38m and 54m in height was built. The influences of operating conditions, such as solid inventory and fluidizing gas velocity, on the axial voidage profile along the riser were assessed. When the gas velocity exceeds the transport velocity, the S-shaped profile of voidage in the riser was established. At the same time, the voidage in top-dilute section reached the saturation carrying capacity, and the solids circulation rate did not vary with the height of the riser nor the solids inventory. It was also found the critical solids inventory for the saturation carrying capacity increases as the riser height increases. When the height was changed from 38m to 54m, the critical solids inventory increased about 25% from about 40kg to about 50kg, and pressure drop in the furnace also increased about 25%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.