Abstract
The joint construction of sluice stations in the coastal plain area is widely used, but due to the complex inflow conditions, it is easy to produce reflux, vortex and other undesirable flow patterns, which have extremely adverse effects on the operation of pumping station units. For a sluice station project into the flow pattern problem, the model test to optimize the flow pattern of the front pool of the pumping station, the pumping station forebay with additional flow isolation pier program. The study found that: rectification scheme, pumping station before the pool flow pattern has a more obvious improvement, 1#, 2# inlet flow uniformity distribution increased by 9% and 2%. There will be no obvious adverse effects on the inflow conditions of the sluice. The optimized scheme has better inlet flow conditions than the original scheme, and the proposed optimized scheme can provide reference experience for other similar projects.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IOP Conference Series: Earth and Environmental Science
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.