Abstract

To solve the problem of poor seismic resistance due to the disadvantages of traditional concrete composite beams, such as heavy self-weight in prefabricated buildings, prestressed specified-density concrete composite beams are proposed herein. First, a mix ratio test of specified-density concrete was performed. Second, five prestressed specified-density composite beams, a prestressed ordinary concrete composite beam, and a prestressed semi lightweight concrete cast-in-situ beam were tested. The influence of the precast concrete height, reinforcement ratio, and concrete materials on the failure mechanism, flexural bearing capacity, and short-term stiffness of the composite beams were analysed. From the results, the specified-density concrete composite beams and the ordinary composite beam had similar ultimate bearing capacities, but the average distance between crack spacings of the former was smaller. The precast concrete height affected the bending performance of the prestressed specified density concrete composite beam insignificantly, but the maximum ultimate bearing capacity of the composite beam could be increased by 35.6% by increasing the reinforcement ratio. The composite beam and the cast-in-place beam exhibited similar load-carrying capabilities and deformation properties. The average crack spacing, cracking load, and ultimate load value of the specified density concrete composite beams calculated according to the China national standard “Code for design of concrete structures” were consistent with the measured values.