Abstract

The filtration performance of the moving bed granular filter with axial flow (MBGF-AF) is investigated through a large cold experiment. The effect of different operation parameters on the filtration performance (collection efficiency, pressure drop) of the axial-flow moving bed filter is investigated in combination with the dust deposition effect and the mechanism of trapping dust by the capturing particles. The results show that the collection efficiency of MBGF-AF is enhanced by decreasing the superficial gas velocity, increasing the inlet dust concentration properly, or decreasing the moving velocity of the capturing particles. A model covering the above operation parameters is established to calculate the collection efficiency of the moving bed granular filter. It is used in a wide range of operating parameters for the MBGFs.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.