Abstract
The technology of film cooling is one of the most effective means of protecting the turbine blades. In this paper, flow structures of the turbine stator blade with six hole-rows at different blowing ratio(M=0.5, 1.0 and 1.5)and setting angles(β=40°, 50°, 60°, 70°, 80° and 90°) was measured by PIV in piston flow type of low-speed wind tunnel laboratory. Velocity was analyzed. Results show that: velocity gradient of suction side was much higher than pressure side and increased with setting angle reduction; Adherence of film is influenced by setting angle and blowing ratio, when M=1.0 and β=70° anchorage dependent is best and suction side is greater than pressure side.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.