Abstract

The widely used evaporators with two different type were experimentally studied in psychrometric calorimeter room using HFO-1234yf as working fluids. The evaporators types are laminated plate and microchannel parallel flow (PF) type. The experimental results compared with R134a system show that cooling capacity has different features in laminated plate evaporator and microchannel PF evaporator under different refrigerant pressure at expansion valve inlet. In general, cooling capacity of laminated plate evaporator of HFO-1234yf is reduced up to 8.0%. But in microchannel PF evaporator, cooling capacity is comparable and/or larger than that of R134a up to 6.5%. The HFO-1234yf evaporator air off temperature deviation is larger than that of R134a evaporator. The air side pressure drop is very close for both evaporators and refrigerants. HFO-1234yf refrigerant side pressure drop is larger than that of R134a for both evaporators.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.