Abstract
In this study, evaporation characteristics of a hydrogen peroxide droplet, 90% purity, was experimentally investigated at elevated temperature (between 400 and 800 °C) and atmospheric pressure under normal gravity. Elevated temperature atmosphere was provided by electric furnace inside the chamber. The range of a droplet size was 1.1 mm to 1.3 mm. The evaporation process of a droplet was recorded by high speed CCD camera. As analysing the image extracted from the camera using the program, evaporation rate of a single droplet was calculated at each ambient temperature. After thermal expansion period, evaporation rate of a hydrogen peroxide droplet followed d2-law but thermal expansion period didn't clearly separate at 400 °C. The evaporation rate increased with increase in ambient temperature. Also thermal decomposition of hydrogen peroxide increased at high temperature.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IOP Conference Series: Earth and Environmental Science
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.