Abstract

In order to solve the problem of poor sealing performance of rotating machinery under the condition of small clearance, a new type of divergent magnetic fluid seal device with small clearance and double magnetic source is designed in this paper. The effect of magnetic fluid injection, tooth number and sealing clearance on the sealing pressure resistance of dual magnetic source divergence were studied and compared with the experimental value of ordinary magnetic fluid seal. The experiment results show that the pressure resistance ability of divergent magnetic fluid seal is at least 3 times that of ordinary magnetic fluid seal, which verifies the correctness of divergent magnetic seal with small clearance and double magnetic source pressure resistance theory, and has important theoretical guiding significance for solving the problem of poor magnetic fluid seal performance under small clearance.