Abstract

Critical heat flux (CHF) is experimentally studied on a relatively large downward-facing surface with a heated stainless steel disk diameter of D = 300 mm in confined space at atmospheric pressure using water as the working fluid. The bulk working fluid is subcooled. The gap size s can be adjusted to 0.9, 2.2, 2.6, 3.0, 3.2, 5.0, 7.0, 10.0, 13.0, 15.6, 19.5, 25.0, 36.0, 51.0 and 77 mm. We found that the average CHF under the present condition is approximately 0.25 MW/m 2 which is only about 23% of which occurs on an upward-facing surface without confined space in pool boiling. The CHF increases with the increase of the gap size when the gap size is smaller than 7 mm and it is a function of Bond and Jakob numbers when the gap size is larger than 7 mm.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.