Abstract
The Effect of gap size to counter current flow limitation (CCFL) in vertical rectangular channel was studied in this paper. Experiment was conducted by using two vertical plate with 1 mm, 2 mm, and 3 mm narrow gap. The initial temperature of plate was decided at 600oC. Flow rate and temperature of cooling water were controlled about 0.09 L/s and 90oC respectively. Non-dimensional superficial velocity for water is 0.05-0.09 and non-dimensional superficial velocity for vapor is 3.20-3.2. The result shows that the existence of CCFL in the vertical rectangular narrow channels. A new correlation for CCFL base on Wallis has been proposed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.