Abstract
Abstract Porous wicks are a key component of loop heat pipes (LHPs). In order to enhance the antigravity and long-distance operation ability of the LHP, a porous wick is required to have the characteristics of high permeability and high capillary suction capability. In this paper, biporous wicks were prepared by salt dissolution pore-forming technology, and a gas resistance testing platform and a capillary suction testing platform were setup to test the samples. The current research studies the effects of different pore-forming agent mass ratios (10%, 30%, and 40%) and different cold pressing pressures (30 kN, 40 kN, 50 kN, and 60 kN) on the porosity, permeability, and the suction speed. The study finds that the porosity, permeability, and the total suction mass of the porous wicks all increase when the NaCl mass increases; the increase of the suction speed is proportional to the increase of the porosity and the permeability, and hence, proportional to the increase of NaCl mass. The total suction mass and suction speed is inversely proportional to cold pressing pressure.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.