Abstract

Given the problems existing in the operation of supercritical 600MW boiler, such as spiral pipe water cooling wall outlet, superheater and reheater wall surface overtemperature easily, the superheater and reheater cooling water amount are too large under high load, and the low load cooling water amount is too small to meet the need of cold reheater heating, the boiler combustion optimization and adjustment are carried out. Through the boiler pulverized coal fineness, air distribution characteristics, swinging Angle of burner and furnace outlet is optimized, such as oxygen level superheater heating surface overtemperature problems are solved, such as the reheater desuperheating water flow under different load can meet the needs of heat supply, at the same time, it also improves the boiler efficiency, effectively improve the safety and economy of the unit.