Abstract

To study energy recovery from low temperature wastewater during industrial production, a water-boiling heat transfer experimental device was built. A casing evaporator with a length of 1450 mm, an inner tube diameter of 30 mm, and an annular space gap of 14.2 mm is taken as the main research object. The boiling heat transfer characteristics of water in the annular tube area of the casing evaporator were experimentally studied by adjusting the inlet temperature (60? 85?C) of hot water and the pressure in the annular tube (12.1-57.6 kPa). The results show that, as the pressure of the system decreases, the boiling phenomenon in the annular tube becomes more intense and the convective heat transfer coeffi-cient increases. The boiling flow and average surface convective heat transfer enhancement rates, ? , were 2.2 and 1.5 when an initial pressure of 1 kPa was used. When the flow rate of the working medium in the annular tube was 1.69 kg?m2/s, the convective heat transfer coefficient gradually increased with the temperature and then stabilized when the inlet temperature reached between 80?C and 85?C. These results reveal the characteristics of boiling-water heat transfer in an annular tube and aid in the design of heat pipe systems for waste-heat recovery.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.