Abstract

Currently, there is a lack of adequate standards for evaluating the integrity inspection cycle of polyethylene (PE) gas pipelines. In this study, a series of photo-oxidation accelerated-aging experimental tests for PE80 gas pipe samples were performed. The attenuation laws of several critical performance parameters, such as micro-morphology, tensile strength, and thermal stability tests, were established. These parameters were determined at different aging times. A novel comprehensive performance evaluation method for pipeline integrity was developed using the analytic hierarchy process, and a reasonable inspection period for pipeline integrity was identified. The results showed that the samples experienced two stages of aging: rapid aging stage and aging platform stage. During the rapid aging stage, the comprehensive evaluation index for the aging performance decreased rapidly. However, the comprehensive evaluation index for the aging performance remained almost unchanged during the aging platform stage.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.